Titration or potentiometer is a instrument used for quantitative chemical analysis.Titra smart is provided with a two point auto calibration and standardisation (zero offset). The potentiometric Autotitrator Titra smart is capable of displaying pH and mV of the sample with temperature compensation. The liquid path comprises Teflon material and glass tight burette which creates chemically inert system for any sensitive analysis. The 21 CFR part 11 compliance has audit trail which logs all the activities with search facility, report generation and printing. There is also a Electronic Signature functionality in Titra smart. As a standard the potentiometric smart Titrator has a manual archive and data backup facility.
Standard Features of Potentiometric Auto Titrator Titra Smart
- User Interactive Design: Easy to operate with protection against invalid entries.
- Vortex Stirrer: For vigorous and homogeneous stirring, with a specially designed glass propeller for total chemical inertness.
- Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette factor for dispensing corrections is available for accurate endpoint calculations.
- Peripheral Connectivity Recognition: The system detects proper connectivity of peripherals (burette, stirrer, electrode) and provides an indication in case of improper connectivity.
- Composite Differential Electrode Amplifier Unit: Used for Potentiometric and KF titrations, providing connectivity to various electrodes. The temperature sensor with a 4-line measurement technique ensures correct temperature indication.
- Large Memory Capacity: For storing methods with scientific parameters, ensuring GLP compliance.
- Standardized Titration Modes: Includes incremental and equilibrium titration methods.
- Automatic Electrode Type Selection: By selecting a titration method, the instrument automatically identifies the appropriate electrode for use.
- Titration Data Display: During titration, the measured variable (electrode potential or pH value) is shown, along with dispensed volume and the number of detected end points (EP).
- User-Selectable End Point (EP) Evaluation: Up to 9 EPs during the run, with calculations by first, last, largest, all, or selected EP. Results and printouts are displayed.
- Sample and Titrant Identification: The system records sample name, titrant name, identification number, date, and electrode type used for authentication. Additionally, daily auto-incremented run numbers, factory-entered customer name, and instrument serial number ensure GLP compliance.
- Manual Titration Capability: Can be used as a dispenser for fixed volume dosing or dilution, with user-defined dose and mV indication.
- Predispense Facility: Selectable dose and time for quick titrant addition without disturbing the titration trend.
- Automatic Molarity Evaluation: For titrant standardization.
- ASTM Compliance: Compliant with ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
- Titrant Temperature Factor: For volume correction.
- Result Recalculation: Facilities for obtaining printouts in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN & TBN for oil samples.
- User-Defined Formula: Allows the use of constant codes (FC 1, FC 2, FC 3, FC 4) for custom calculations.
- Reprocessing of Threshold and EP: Recalculation of EP without the need for a new run.
- Statistic Function: For analyzing Mean, Standard Deviation (S.D.), Relative Standard Deviation (R.S.D.), and Coefficient of Variation (C.V.) of the last 10 repeat runs, with results available for viewing or printing.
- User-Programmed Selectivity for Report Format (GLP Compliant):
- A) Report with titration parameters and results.
- B) Data table with mV, pH, mV, mV/ml, 2nd derivative & volume (μl).
- C) Graphics report showing mV vs μl titration curve.
- D) Graphics report of the 1st derivative graph vs μl titration curve.
- E) Graphical report of the 2nd derivative curve.
- F) Report of method parameters.
- G) Condensed report of titration parameters and results.
- H) Auto evaluation report for multi EP samples (e.g., EP1, EP2-EP).
- Reports Accessibility: Reports can be obtained even after resetting, power off, or power failure conditions.
- Time Display: With run time indication for report printout.
- Balance Interface: To directly transfer the sample weight.
- Titration Mode Conversion: TITRA can be converted to perform Karl Fischer titrations by changing the burette assembly. All specifications of LABINDIA Karl Fischer Titrator are applicable.
- Online Graphic Display: To analyze the sample reaction trend.
- Syringe Filled Status Display: On the screen for better monitoring.
21 CFR PART 11 COMPLIANCE
- Audit Trail: For all activities, with search facilities, report generation, and printing.
- 200 User IDs: Alphanumeric entries for user name, password, and role-based privilege selection.
- Multi-Level Roles: With password protection and complexity.
- User Authentication: Performed for every operation done by the user.
- Customizable PDF Reports: Reports can be printed in a customizable PDF format.
- USB Printing: Eliminates the need for a serial port. Users can take printouts on any local or network printer.
- Electronic Signature Functionality: For security and compliance.
- Manual Archive & Data Backup Facility: Available to ensure data integrity.