Labindia Analytical Potentiometric Titrator Titra+ comes with quick interchangeable imported burette assemblies with intelligent recognition for its volume size.This potentiometric autotitrator is perfect for all types of industrial applications. The Titra+ has composite differential electrode amplifier unit for potentiometric and voltametric/Karl Fisher titration having connectivity to various electrodes. Three standard modes of titration namely incremental, equilibrium and cut-off mode is provided to perform all types of titrations. There is a real time clock for time display and report printout with run time indication. With a balance interface to directly transfer the weight. 50 methods can be stored and report of method parameter can be printed in Titra+.
Standard Features of Automatic Titrator
- Advanced Microcontroller-Based Design: User-friendly, state-of-the-art product design with alphanumeric splash waterproof polyester soft keys for the keyboard. User-interactive software in dialogue mode for ease of operation, with protection against invalid entries.
- Vortex Stirrer: For vigorous and homogeneous stirring with a specially designed glass propeller for total chemical inertness.
- Quick Interchangeable Burette Assemblies: Imported burette assemblies with intelligent recognition for volume size. Burette factor for dispensing corrections is available for true endpoint calculations.
- Composite Differential Electrode Amplifier Unit: For potentiometric and voltametric/KF titrations, with connectivity to various electrodes. Temperature sensor with 4-line measurement technique ensures correct temperature indication.
- Three Standardized Titration Modes: Incremental, equilibrium, and cut-off by pH mode to perform almost all types of titration. The instrument prints the appropriate electrode type based on the selected titration method.
- Measured Variable Display: During titration, the measured variable (electrode potential or pH value) is displayed along with the dispensed volume and number of End Points (EP) detected.
- User-Selectable End Point (EP) Evaluation: Up to 9 EP during the run, with calculation by first, last, largest, all, or selected EP, with results displayed and printed.
- Alphanumeric Entries: Sample name, titrant name, identification number, date, and electrode type used for authentication. Includes factory-entered customer name and instrument serial number on report printouts, ensuring GLP compliance.
- Dispenser Functionality: Can be used as a dispenser for fixed-volume dosing or dilution, allowing for manual titration with user-defined doses and mV indication.
- Pre-Dispense Facility: Selectable dose and time for quick titrant addition without disturbing the titration trend.
- Automatic Evaluation of Molarity: For titrant standardization, with storage of 20 molarities and retrieval for calculation.
- Compliance: ASTM D664, D2896 & D4739 for TAN and TBN analysis for oil samples.
- Titrant Temperature Factor: For volume correction.
- Result Recalculation Facility: Printouts available in different units such as molarity, factor, % assay (wt), % volume (ml), ppm, mg/l, mg/g, ml/g, g/l, meq/l, mol/kg, TAN, & TBN for oil samples.
- Reprocessing of Threshold and EP Calculation: Recalculation of EP without performing a new run.
- Statistical Function: Run selectivity to calculate mean, standard deviation (S.D.), relative standard deviation (R.S.D.), and coefficient of variation (C.V.) for the last 10 repeat run results, which can be viewed or printed.
- User-Programmed Selectivity for Report Format: Complying with GLP requirements:
- Report with parameters and results.
- Data table with mV, pH, mV, mV/ml, 2nd derivative, and volume (μl).
- Graphical report showing mV vs. μl titration curve.
- Graphical report of 1st derivative graph vs. μl titration curve.
- Graphical report of 2nd derivative curve.
- Report of method parameters for 50 methods.
- Condensed report of titration parameters and results.
- Auto evaluation report for multi-EP samples (EP1, EP2-EP1, etc.).
- Report Access: Reports can be obtained even after resetting/power off/power failure.
- Real-Time Clock (RTC): For time display and report printout with runtime indication.
- Balance Interface: Direct transfer of sample weight.
- Two-Tier Password Protection: Admin and user-level protection for method editing.
- Conversion to Karl Fischer Titrations: TITRA can be converted for Karl Fischer titrations by changing the burette assembly. All specifications of LABINDIA Karl Fischer Titrator are applicable.